BVCSX - SPRAY ADHESIVE TM-250,76240
- MSDS: BVCSX
- Manufacturer: OSBORN MFG
- Product Name: SPRAY ADHESIVE TM-250,76240
- National Stock Number: 8040-00N049311
Product Identification
Product ID:SPRAY ADHESIVE TM-250,76240
MSDS Date:01/06/1989
FSC:8040
NIIN:00N049311
MSDS Number: BVCSX
Responsible Party
CLEVELAND, OH 44114
US
Emergency Phone: 216-467-4195
Info Phone: 216-361-1900
Cage: GO998
Contractor
Telephone: 216-361-1900
Cage: GO998
Ingredients
HEXANE
CAS: 110-54-3
RTECS: MN9275000
Fraction By Weight: 20%
OSHA PEL 5000 PPM
ACGIH TLV: 50 PPM
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
METHANE, DICHLORO-; (METHYLENE CHLORIDE)
CAS: 75-09-2
RTECS: PA8050000
Fraction By Weight: 44%
OSHA PEL 500 PPM, 1000 C
ACGIH TLV: 50 PPM
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
PROPANE
CAS: 74-98-6
RTECS: TX2275000
Fraction By Weight: <27%
OSHA PEL 1000 PPM
ACGIH TLV: SIMPLE ASPHYXIANT
PROPANE, 2-METHYL-; (ISOBUTANE)
CAS: 75-28-5
RTECS: TZ4300000
Fraction By Weight: <27%
OSHA PEL N/K
ACGIH TLV: N/K
NONHAZARDOUS INGREDIENTS
Fraction By Weight: 93%
OSHA PEL N/K
ACGIH TLV: N/K
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: MAY CAUSE DIZZ/NARCOS IN HIGH
VAP CONC. WILL CAUSE DEFAT OF SKIN. EFTS ARE REVERSIBLE. LONG TERM
EXPOS (YEARS) MAY CAUSE LUNG, LIVER/KIDNEY DAMAGE. SOLVENTS LISTED
HAVE BEEN REPORTED TO AFFECT CENTRAL NERVOUS SYSTEM. METHYLENE
CHLORIDE WILL HAVE AN EFT ON CARDIOVASCULAR SYS. INHAL: DFCLTY IN
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:METHYLENE CHLORIDE: IARC MONO SUPP, VOL
7, PG 194, 1987: GRP 2B. NTP 6TH ANNUAL REPORT ON CARCINS, 1991:
ANTIC (SUPDAT)
Effects of Overexposure:HLTH HAZ:BRTHG. SKIN:REDNESS. INGEST: VOMITING.
CHLOROCARBON MATLS HAVE PRDCD SENSIT OF MYOCARDIUM TO EPINEPHRINE
IN LAB ANIMALS & COULD HAVE SIMILAR EFT IN HUMANS. ADRENOMIMETICS
(E.G., EPINEPHRINE) MAY BE CONTRAINDICATED EXCEPT FOR
LIFE-SUSTAINING USES IN HUMANS ACUTELY OR CHRONICALLY EXPOSED TO
CHLOROCARBONS .
Medical Cond Aggravated by Exposure:HEART DISEASES; RESPIRATORY
DISORDERS.
First Aid
First Aid:INHAL: GIVE OXYGEN. INGEST: DO NOT INDUCE VOMITING. GASTRIC
LAVAGE. EYES: WASH WITH WATER FOR AT LEAST 15 MINUTES. SKIN: WASH
WITH WATER.
Fire Fighting
Flash Point Method:TCC
Flash Point:-40F,-40C
Lower Limits:1.8%
Upper Limits:12%
Extinguishing Media:USE WATER FOG, DRY CHEMICAL/CARBON DIOXIDE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
AND FULL PROTECTIVE EQUIPMENT . AEROSOL CANS MAY RUPTURE WHEN
HEATED.
Unusual Fire/Explosion Hazard:HEATED CANS MAY BURST. THERMAL
DECOMPOSITION PRODUCTS MAY INCLUDE HCL AND PHOSGENE .
Accidental Release
Spill Release Procedures:USE ABSORBENT SWEEPING COMPOUND TO SOAK UP
MATERIAL. PUT INTO CONTAINER. DISPOSE AS HAZARDOUS WASTE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:KEEP AWAY FROM HEAT, SPARKS/OPEN
FLAME. STORE @ TEMPS BELOW 120F.
Other Precautions:WHEN SPRAYING MORE THAN 1/2 CAN CONTINUOUSLY/MORE
THAN 1 CAN CONSECUTIVELY, USE NIOSH/MSHA APPRVD RESP. NO SMOKING IN
AREA OF USE. DO NOT USE IN GEN VICIN OF ARC WELD, OPEN FLAMES/HOT
SURF. HEAT &/OR UV RADIA MAY CAUSE FORM OF HCL &/(SUPDAT
Exposure Controls
Respiratory Protection:NIOSH/MSHA APPROVED SCBA IF ABOVE TLV LIMIT
EXCEEDING.
Ventilation:LOCAL EXHAUST.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS .
Other Protective Equipment:LONG SLEEVE AND LONG PANTS.
Work Hygienic Practices:DO NOT SMOKE WHILE USING. WASH HANDS AFTER USE.
Supplemental Safety and Health
EXPLAN OF CARCIN: TO BE CARCIN. ANIMAL: LUNG, LIVER, SALIVARY, MAMMARY
GLAND (TUMORS). OTHER PREC: OR PHOSGENE .
Chemical Properties
Boiling Pt:B.P. Text:>-40F,>-40C
Vapor Pres:45PSIG
Vapor Density:4(HVR/AIR)
Spec Gravity:0.8(H*2O=1)
Evaporation Rate & Reference:>5(BUTYL ACETATE=1)
Solubility in Water:NIL
Appearance and Odor:YELLOW/SOLVENT ODOR
Stability
Stability Indicator/Materials to Avoid:YES
METHYLENE CHLORIDE WILL REACT WITH ACTIVE METALS. SOLVENTS LISTED ARE
INCOMPATIBLE WITH STRONG OXIDIZERS.
Stability Condition to Avoid:HIGH TEMPERATURES.
Hazardous Decomposition Products:IN FIRE WILL DECOMPOSE TO WATER,
CARBON DIOXIDE, HALOGEN ACIDS AND PHOSGENE.
Disposal
Waste Disposal Methods:DISPOSE AS HAZARDOUS WASTE I/A/W EPA RCRA.
DISPOSE OF I/A/W FEDERAL, STATE AND LOCAL REGULATIONS .
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.